EMF and Internal Resistance from a Voltage-Current Graph
Find emf and internal resistance from a voltage-current graph. Check the intercept, negative gradient, milliamp conversion and reversed-axis pitfalls.

| Topic | Exam Prep |
|---|---|
| Focus | Physics |
| Read time | 5 min |
| Words | 915 |
| Published | 24 Nov 2026 |
| Best for | Parents & students |
A graph of terminal voltage against current can give both the emf and internal resistance of a cell. The main traps are reading the wrong intercept, losing the negative sign of the gradient and treating milliamps as amps.
This guide interprets supplied written data and best-fit lines. It is not an instruction to build a circuit or short a battery. For the broader circuit model, see our current electricity practice page. Here the new task is extracting quantities from axes and gradients.
Match the equation to the plotted axes
Assume the cell supplies current to an external load, with current I positive out of its positive terminal. Over the readings used, take emf E and internal resistance r as approximately constant. Terminal voltage is then V = E - Ir.
For V on the vertical axis and I on the horizontal axis, compare this with y = c + mx. The vertical intercept c is E, measured in volts. The gradient m is -r, measured in volts per ampere, equivalent to ohms.
This correspondence depends on the axes. The phrase “a voltage-current graph” is not enough: read which quantity is vertical and which is horizontal before applying a remembered slope rule.
Calculate a gradient from two line points
Suppose two clearly readable points on a supplied straight best-fit line are (0.10 A, 1.44 V) and (0.50 A, 1.20 V). These are invented practice coordinates, not experimental measurements from an actual cell.
Gradient = change in V / change in I = (1.20 - 1.44) / (0.50 - 0.10) = -0.24 / 0.40 = -0.60 V/A.
Because gradient = -r, internal resistance r = 0.60 Ω. The downward slope is negative; the resistance in this ordinary source model is positive. Do not report r = -0.60 Ω.
Choose well-separated readable points on the best-fit line. They need not be original data points. Using two adjacent scattered measurements instead can make a small reading difference dominate the result.
Recover the emf from the intercept
If the vertical intercept is visible and readable, its value gives E directly. Otherwise use E = V + Ir with a point on the fitted line and the internal resistance just found.
Using the first point, E = 1.44 + 0.10 × 0.60 = 1.50 V. Using the second, E = 1.20 + 0.50 × 0.60 = 1.50 V again. Agreement checks the arithmetic.
The resulting line is V = 1.50 - 0.60I when V is in volts and I in amperes. At I = 0.30 A, it predicts V = 1.32 V. That prediction lies between the two given line points, as expected.
Do not divide one voltage by one current
Using 1.20 / 0.50 gives 2.40 Ω, not the internal resistance. The V-I line does not pass through the origin, so V/I is not its gradient.
Under the stated discharge model, terminal V divided by load current describes the external load resistance at that operating point. Internal resistance comes from the change in voltage divided by the change in current, with the sign handled through gradient = -r.
Convert a milliamp axis before quoting ohms
The same two coordinates could be labelled 100 mA and 500 mA. Dividing -0.24 V by 400 mA gives -0.00060 V/mA.
One ampere is 1,000 milliamperes. Therefore this is -0.60 V/A, giving r = 0.60 Ω, not 0.00060 Ω. The safest working is often to convert each current coordinate to amperes before calculating the gradient.
Axis multipliers matter too. If the graph labels current as I / 10⁻³ A, a horizontal coordinate of 100 represents 0.100 A. Write the physical current values before subtracting them.
Rearrange again if the axes are reversed
For current on the vertical axis and voltage on the horizontal axis, rearrange the model: I = E/r - V/r. Its gradient is now -1/r, in A/V, rather than -r.
For the same example, gradient = -1 / 0.60, approximately -1.67 A/V. Recover resistance by taking the negative reciprocal of the gradient. The current-axis intercept is E/r = 2.50 A, not an emf in volts. The voltage-axis intercept remains 1.50 V.
That extrapolated current intercept belongs to the simplified model. It is not an instruction to short-circuit the cell or a guarantee about its actual current under extreme conditions.
Check whether a straight-line interpretation is justified
A changing cell state, heating or measurement drift can undermine the assumption of constant E and r. A visibly curved or inconsistent dataset should not be forced into this simple interpretation without qualification.
Where a question asks for uncertainty, follow its graph instructions, including any permitted steepest and shallowest lines. Two exact-looking coordinates do not make an experimental estimate exact.
For a fresh written check, line points (0.20 A, 2.36 V) and (0.80 A, 2.00 V) give gradient -0.60 V/A, internal resistance 0.60 Ω and emf 2.48 V.
Frequently asked questions
Which intercept gives emf on a V-against-I graph?
The voltage-axis intercept, where current is zero.
Why is the gradient negative?
In the stated discharge model, terminal voltage decreases as current increases.
Can I use V divided by I for internal resistance?
Not here. Use the fitted-line gradient and its axis units.
Does reversing the axes leave the slope rule unchanged?
No. For I against V, gradient is -1/r rather than -r.
Sources
Graph interpretation checked against the University of Birmingham's emf teaching resource. The discharge model and its limitations are checked against OpenStax, Electromotive Force: Terminal Voltage. Numerical coordinates here are original practice.
Related articles
- Total Expenditure Method: Classify Price Elasticity of Demand
- Potometer Calculations: Bubble Speed and Water Uptake Rate
- A Spring Cut in Half: Force Constant and Period Explained
- Apparent Weight in a Lift: Why Moving Down Can Feel Heavier
- Vernier Calipers Class 11: Positive and Negative Zero Error
Explore related tuition services: physics tuition · home tuition · online tuition