A measured gas volume collected over water is usually not a sample of dry gas alone. Water vapour also occupies the collection space and contributes to its pressure. Before using PV = nRT to find the amount of the gas of interest, separate that contribution from the total pressure.

The worked example below is an invented written-data problem, not instructions for carrying out a reaction. It assumes ideal-gas behaviour, a gas that does not react with water, negligible loss by dissolution, and equilibrium with liquid water at the stated temperature. The water levels inside and outside the collection vessel are equal.

Identify which pressure the question gives

Dalton's law says that the total pressure of an ideal gas mixture is the sum of its component partial pressures. If the trapped mixture contains only the collected gas and water vapour, write:

Ptotal = Pgas + Pwater.

Therefore the dry-gas partial pressure is Pgas = Ptotal - Pwater. “Dry” here labels the pressure attributable to the gas alone. It does not mean that somebody has physically dried the sample.

Equal water levels matter because they let the trapped mixture's total pressure equal atmospheric pressure. Without that condition, or a separately supplied total gas pressure, a water-column pressure correction may be needed. Do not assume that every atmospheric reading is automatically the pressure inside any collection vessel.

Correct the pressure before calculating moles

Suppose a sample occupies 0.400 L at 25.0 degrees C. The total pressure is 750.0 torr. Use the supplied water vapour pressure of 23.8 torr at this temperature. Assume equal water levels and no additional gas such as trapped air.

The dry-gas pressure is 750.0 - 23.8 = 726.2 torr. For a gas constant expressed in litre-atmosphere units, convert using 760 torr = 1 atm:

Pgas = 726.2/760 = 0.95553 atm, retaining extra digits for the calculation.

Convert temperature to kelvin: T = 25.0 + 273.15 = 298.15 K. The volume is already in litres. With R = 0.082057 L atm mol-1 K-1:

ngas = Pgas V/(RT) = (0.95553 x 0.400)/(0.082057 x 298.15) = 0.0156 mol, to three significant figures.

This is the amount of the collected gas, excluding water vapour. It is not the total number of moles of everything in the wet mixture.

Keep the measured volume in the calculation

Subtracting water vapour pressure does not mean subtracting a separate visible volume of water vapour from the cylinder reading. In the ideal mixture, each gas occupies the available collection volume. Use the measured 0.400 L with the dry-gas partial pressure when calculating its moles.

A different question might ask what volume the dry gas would occupy after a specified change of pressure or temperature. That needs another gas-law calculation. Do not change the measured volume halfway through this mole calculation without a stated new condition.

Check the direction of the error

If you incorrectly use the full 750.0 torr in PV = nRT, the result is about 0.0161 mol. That answer counts the pressure contribution of water vapour as though it came from the collected gas.

At fixed volume and temperature, calculated moles are proportional to the pressure inserted. Since total pressure is greater than dry-gas pressure, ignoring the vapour correction must overestimate the amount of the gas of interest.

For these supplied numbers, the ratio of the wrong result to the correct result is 750.0/726.2, approximately 1.0328. The overestimate is about 3.28%. This percentage belongs only to this constructed example, not to all gas-collection measurements.

Match the vapour pressure to the temperature

Water vapour pressure depends on temperature. Use the value supplied for the sample temperature, or a suitable source table if the question requires one. The 23.8 torr value used here appears at 25 degrees C in OpenStax's water-vapour-pressure table.

Do not use that number automatically at a different temperature. Likewise, never subtract torr from atmospheres: convert the pressure units first, then subtract. Keep the units compatible with the chosen value of R.

The two-component formula also needs its stated scope. If trapped air contributes pressure, total pressure minus water vapour pressure includes that air as well. If the collected gas reacts with water or dissolves appreciably, this simple model may not recover the amount originally produced.

Frequently asked questions

Why subtract water vapour pressure?

The measured total pressure includes both the collected gas and water vapour. Subtraction isolates the partial pressure belonging to the gas of interest.

Does the dry gas use the whole measured volume?

Yes, in this ideal-mixture model. Use the collection volume with the gas's partial pressure, rather than removing an imagined separate vapour volume.

Can I use atmospheric pressure when water levels differ?

Not automatically. Unequal levels can create a pressure difference. You need the trapped mixture's total pressure or an appropriate water-column correction.

What if the pressure is already for dry gas?

Use that dry-gas pressure directly. Subtracting water vapour pressure again would apply the correction twice and underestimate the amount of gas.