EZ Tuitions Logo
EZ Tuitions
Back to Blog

Stopping Potential Graph: Find Threshold and Work Function

5 min read• 11/26/2026• By Ananya Sharma, Academic Content Lead, EZ Tuitions• Exam Prep

Use two stopping-voltage readings to find slope, intercept, threshold frequency and work function. Avoid scaled-axis and eV-versus-volt errors.

A student looking at physics laboratory equipment.
Key facts about this article
TopicExam Prep
FocusPhysics
Read time5 min
Words906
Published26 Nov 2026
Best forParents & students

Two stopping-potential measurements can reveal more than the voltage needed to stop photoelectrons. They can give the slope of a voltage-frequency graph, the threshold frequency and the surface work function. The key is to treat the graph as a straight line and read its axis units before doing arithmetic.

This worked example uses invented, idealised data for one unchanged surface. It is a classroom calculation, not a measurement of a named metal or a claim about experimental precision. Stopping potential Vs means a positive retarding-voltage magnitude throughout.

Write the equation in straight-line form

Einstein's photoelectric equation connects maximum electron kinetic energy to incident frequency: Kmax = hf - φ. The stopping-voltage relation is Kmax = eVs, where e is the positive magnitude of the electron charge. Combining them gives eVs = hf - φ.

Divide by e to get Vs = (h/e)f - φ/e. Compare this with y = mx + c. On a graph of stopping magnitude in volts against frequency in hertz, the slope is h/e and the vertical intercept is -φ/e.

The threshold frequency f0 is the horizontal intercept. Set Vs = 0 to obtain f0 = φ/h. The negative vertical intercept is an extrapolation of the straight line, not a measured negative kinetic energy below threshold.

Use two stopping-voltage measurements

Suppose the same surface gives Vs = 0.828 V at f = 7.00 × 10^14 Hz and Vs = 1.656 V at f = 9.00 × 10^14 Hz. Assume both measurements are above threshold and follow the ideal straight-line relation.

Subtract the first equation from the second. Because the surface has not changed, its work function cancels:

  1. Voltage change: ΔVs = 1.656 - 0.828 = 0.828 V.
  2. Frequency change: Δf = (9.00 - 7.00) × 10^14 = 2.00 × 10^14 Hz.
  3. Slope: m = ΔVs/Δf = 4.14 × 10^-15 V s.

Frequency has units s^-1, so volts per hertz are volt seconds. Do not write the slope simply as volts. The difference method needs both readings to belong to the same surface under comparable conditions; combining unrelated metals would not cancel one common work function.

Recover the intercept and threshold frequency

Use c = Vs - mf with either point. From the first measurement, c = 0.828 - (4.14 × 10^-15)(7.00 × 10^14) = 0.828 - 2.898 = -2.070 V.

The fitted line is therefore Vs = (4.14 × 10^-15 V s)f - 2.070 V. Its horizontal intercept satisfies 0 = mf0 + c, giving f0 = -c/m = 2.070/(4.14 × 10^-15) = 5.00 × 10^14 Hz.

An equivalent route avoids finding c first: f0 = f1 - Vs1/m. Substitution gives 7.00 × 10^14 - 2.00 × 10^14 = 5.00 × 10^14 Hz. Both routes use the same straight-line equation, so they should agree.

Convert the intercept into work function

Since c = -φ/e, the work function is φ = -ec. A vertical intercept of -2.070 V therefore corresponds to φ = 2.070 eV. The numerical match does not mean electronvolts and volts are interchangeable units: one is energy, the other electric potential difference.

If the question supplies e = 1.60 × 10^-19 C and asks for joules, multiply 2.070 V by that charge to obtain approximately 3.31 × 10^-19 J. If it asks for Planck's constant from the data, use h = em, approximately 6.62 × 10^-34 J s with the same rounded charge.

If dimensional checks are slowing you down, first practise the Units and Measurements worked examples. Then return to the voltage-frequency slope and keep the axis scale attached to every calculation.

Read a scaled frequency axis carefully

A graph might label its horizontal axis f/(10^14 Hz), with plotted readings 7 and 9. Its numerical slope is then 0.414 V per axis unit, not 0.414 V s. Divide by 10^14 Hz per axis unit to recover 4.14 × 10^-15 V s.

As a check, inserting 9.00 × 10^14 Hz into the recovered line returns 1.656 V. Increasing intensity at fixed frequency would not shift that stopping magnitude in this single-photon model. Below threshold, a negative extrapolated voltage is not a physical stopping measurement because photoemission does not occur.

Frequently asked questions

What is the slope of a stopping-potential graph?

For stopping magnitude in volts plotted against frequency in hertz, the slope is h/e in volt seconds. A scaled frequency axis changes the numerical slope read from the graph.

How do I find threshold frequency from two readings?

First calculate m = ΔVs/Δf for the same surface. Then use f0 = f1 - Vs1/m, keeping the frequency units consistent with those used to calculate the slope.

Does the negative intercept mean negative work function?

No. The vertical intercept is -φ/e, so its sign is negative for a positive work function. The work function is recovered by multiplying the intercept by -e.

Can I combine measurements from different metals?

Not for this cancellation method. Different surfaces can have different work functions, so subtracting their equations does not isolate the shared slope from just two arbitrary points.

Sources and practice scope

NCERT's Dual Nature of Radiation and Matter chapter derives the stopping-voltage line and includes a slope exercise. OpenStax's photoelectric-effect discussion explains the energy relation and stopping-potential measurements. The two-point data and calculations above are original hypothetical practice.

Photo: cottonbro studio / Pexels, used under the Pexels License, cropped and resized. The image shows a physics-laboratory setting, not the specific photoelectric apparatus described.

Explore related tuition services: physics tuition · home tuition · online tuition